WTTC & ITC (Direct Burial)
WTTC, Direct Burial (ITC)
Wind Turbine Tray Cable (WTTC)
WTTC cable is designed to withstand extreme, harsh conditions in wind applications like oil, abraison, extreme temperatures, water, constant movement, and more. These cables are rated to 1000V and are designed with high performance jacketing and insulation mateirals that provide protection from sunlight and oil.
Instrumentation Tray Cable (ITC)/ Direct Burial Cable
The most common type of Power Limited Tray Cable (PLTC) that is specified for use in industrial settings is type ITC. These cables are rated to the UL2250 standard and for 300V applications like instrumentation and control circuits, as signal cables. Many ITC and PLTC cables are interchangable today due to their dual-ratings and identical materials and construction.
-
221809 - LAPP ÖLFLEX® TRAY II Unshielded Flexible Tray Cable - 18 AWG 9 Conductor - BlackPart #: OLF221809
Mfg #: 221809
Manufacturer: LAPPExtremely oil-resistant and flexible tray cable
SERIES: ÖLFLEX® TRAY II / TRAY II CY
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.429
NOMINAL OD (MM): 10.9
VOLTAGE: 600V
TRAY RATINGS: UL ITC-ER, UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC, Direct Burial (ITC)
UL STYLE / STANDARD: UL 13, UL 1063, UL 1277, UL 1690, UL 2250
-
601803CY - LAPP ÖLFLEX® 190CY Shielded Multiconductor Cable - 18 AWG 3 Conductor - GrayPart #: OLF601803CY
Mfg #: 601803CY
Manufacturer: LAPPExtremely oil-resistant flexible power and control cable
SERIES: ÖLFLEX® 190 / 190 CY
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Braid
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.367
NOMINAL OD (MM): 9.3
VOLTAGE: 600V
TRAY RATINGS: UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL WTTC
UL STYLE / STANDARD: UL 13, UL 2277
-
601807 - LAPP ÖLFLEX® 190 Unshielded Multiconductor Cable - 18 AWG 7 Conductor - GrayPart #: OLF601807
Mfg #: 601807
Manufacturer: LAPPExtremely oil-resistant flexible power and control cable
SERIES: ÖLFLEX® 190 / 190 CY
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.367
NOMINAL OD (MM): 9.3
VOLTAGE: 600V
TRAY RATINGS: UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL WTTC
UL STYLE / STANDARD: UL 13, UL 2277
-
221404 - LAPP ÖLFLEX® TRAY II Unshielded Flexible Tray Cable - 14 AWG 4 Conductor - BlackPart #: OLF221404
Mfg #: 221404
Manufacturer: LAPPExtremely oil-resistant and flexible tray cable
SERIES: ÖLFLEX® TRAY II / TRAY II CY
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.392
NOMINAL OD (MM): 10
VOLTAGE: 600V
TRAY RATINGS: UL ITC-ER, UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC, Direct Burial (ITC)
UL STYLE / STANDARD: UL 13, UL 1063, UL 1277, UL 1690, UL 2250
-
601403 - LAPP ÖLFLEX® 190 Unshielded Multiconductor Cable - 14 AWG 3 Conductor - GrayPart #: OLF601403
Mfg #: 601403
Manufacturer: LAPPExtremely oil-resistant flexible power and control cable
SERIES: ÖLFLEX® 190 / 190 CY
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.356
NOMINAL OD (MM): 9
VOLTAGE: 600V
TRAY RATINGS: UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL WTTC
UL STYLE / STANDARD: UL 13, UL 2277
-
2216030 - LAPP ÖLFLEX® TRAY II CY Shielded Flexible Tray Cable - 16 AWG 3 Conductor - BlackPart #: OLF2216030
Mfg #: 2216030
Manufacturer: LAPPExtremely oil-resistant and flexible tray cable
SERIES: ÖLFLEX® TRAY II / TRAY II CY
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Braid
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.35
NOMINAL OD (MM): 8.9
VOLTAGE: 600V
TRAY RATINGS: UL ITC-ER, UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC, Direct Burial (ITC)
UL STYLE / STANDARD: UL 13, UL 1063, UL 1277, UL 1690, UL 2250
-
601605 - LAPP ÖLFLEX® 190 Unshielded Multiconductor Cable - 16 AWG 5 Conductor - GrayPart #: OLF601605
Mfg #: 601605
Manufacturer: LAPPExtremely oil-resistant flexible power and control cable
SERIES: ÖLFLEX® 190 / 190 CY
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.375
NOMINAL OD (MM): 9.5
VOLTAGE: 600V
TRAY RATINGS: UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL WTTC
UL STYLE / STANDARD: UL 13, UL 2277
-
221605 - LAPP ÖLFLEX® TRAY II Unshielded Flexible Tray Cable - 16 AWG 5 Conductor - BlackPart #: OLF221605
Mfg #: 221605
Manufacturer: LAPPExtremely oil-resistant and flexible tray cable
SERIES: ÖLFLEX® TRAY II / TRAY II CY
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.381
NOMINAL OD (MM): 9.7
VOLTAGE: 600V
TRAY RATINGS: UL ITC-ER, UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC, Direct Burial (ITC)
UL STYLE / STANDARD: UL 13, UL 1063, UL 1277, UL 1690, UL 2250
-
601604 - LAPP ÖLFLEX® 190 Unshielded Multiconductor Cable - 16 AWG 4 Conductor - GrayPart #: OLF601604
Mfg #: 601604
Manufacturer: LAPPExtremely oil-resistant flexible power and control cable
SERIES: ÖLFLEX® 190 / 190 CY
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.345
NOMINAL OD (MM): 8.8
VOLTAGE: 600V
TRAY RATINGS: UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL WTTC
UL STYLE / STANDARD: UL 13, UL 2277
-
2218030 - LAPP ÖLFLEX® TRAY II CY Shielded Flexible Tray Cable - 18 AWG 3 Conductor - BlackPart #: OLF2218030
Mfg #: 2218030
Manufacturer: LAPPExtremely oil-resistant and flexible tray cable
SERIES: ÖLFLEX® TRAY II / TRAY II CY
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Braid
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.322
NOMINAL OD (MM): 8.2
VOLTAGE: 600V
TRAY RATINGS: UL ITC-ER, UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC, Direct Burial (ITC)
UL STYLE / STANDARD: UL 13, UL 1063, UL 1277, UL 1690, UL 2250