WTTC & ITC (Direct Burial)
WTTC, Direct Burial (ITC)
Wind Turbine Tray Cable (WTTC)
WTTC cable is designed to withstand extreme, harsh conditions in wind applications like oil, abraison, extreme temperatures, water, constant movement, and more. These cables are rated to 1000V and are designed with high performance jacketing and insulation mateirals that provide protection from sunlight and oil.
Instrumentation Tray Cable (ITC)/ Direct Burial Cable
The most common type of Power Limited Tray Cable (PLTC) that is specified for use in industrial settings is type ITC. These cables are rated to the UL2250 standard and for 300V applications like instrumentation and control circuits, as signal cables. Many ITC and PLTC cables are interchangable today due to their dual-ratings and identical materials and construction.
-
251633IBK - LAPP ÖLFLEX® AUTO-I - 16 AWG 33 Conductors - GrayPart #: OLF251633IBK
Mfg #: 251633IBK
Manufacturer: LAPPHeavy duty flexible tray cable with color-coded conductors for DC or AC control wiring
SERIES: ÖLFLEX® AUTO-I
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Elastomer (TPE)
NOMINAL OD (IN): 0.816
NOMINAL OD (MM): 20.7
VOLTAGE: 1000V
TRAY RATINGS: UL TC-ER
STANDARDS/APPROVALS: UL Approved, CE Approved, UL WTTC
-
251642IBK - LAPP ÖLFLEX® AUTO-I - 16 AWG 42 Conductors - GrayPart #: OLF251642IBK
Mfg #: 251642IBK
Manufacturer: LAPPHeavy duty flexible tray cable with color-coded conductors for DC or AC control wiring
SERIES: ÖLFLEX® AUTO-I
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Elastomer (TPE)
NOMINAL OD (IN): 0.95
NOMINAL OD (MM): 24.1
VOLTAGE: 1000V
TRAY RATINGS: UL TC-ER
STANDARDS/APPROVALS: UL Approved, CE Approved, UL WTTC
-
251649IBK - LAPP ÖLFLEX® AUTO-I - 16 AWG 49 Conductors - GrayPart #: OLF251649IBK
Mfg #: 251649IBK
Manufacturer: LAPPHeavy duty flexible tray cable with color-coded conductors for DC or AC control wiring
SERIES: ÖLFLEX® AUTO-I
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Elastomer (TPE)
NOMINAL OD (IN): 1.005
NOMINAL OD (MM): 25.5
VOLTAGE: 1000V
TRAY RATINGS: UL TC-ER
STANDARDS/APPROVALS: UL Approved, CE Approved, UL WTTC
-
251665IBK - LAPP ÖLFLEX® AUTO-I - 16 AWG 65 Conductors - GrayPart #: OLF251665IBK
Mfg #: 251665IBK
Manufacturer: LAPPHeavy duty flexible tray cable with color-coded conductors for DC or AC control wiring
SERIES: ÖLFLEX® AUTO-I
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Elastomer (TPE)
NOMINAL OD (IN): 1.123
NOMINAL OD (MM): 28.5
VOLTAGE: 1000V
TRAY RATINGS: UL TC-ER
STANDARDS/APPROVALS: UL Approved, CE Approved, UL WTTC
-
301802STP - LAPP UNITRONIC® 300 STP Data, Signal & Control Cable - 18 AWG/2 Pair - GrayPart #: OLF301802STP
Mfg #: 301802STP
Manufacturer: LAPPFlexible 300V multi-pair industrial communication & signal cable; shielded
TYPE: Data, Signal & Control
SERIES: UNITRONIC® 300 STP
CONDUCTOR MATERIAL: Tinned copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Foil Braid
JACKET MATERIAL: PVC
NOMINAL OD (IN): 0.422
NOMINAL OD (MM): 10.7
VOLTAGE: 300V
TRAY RATINGS: UL ITC-ER, UL PLTC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, Direct Burial (ITC)
-
221818 - LAPP ÖLFLEX® TRAY II Unshielded Flexible Tray Cable - 18 AWG 18 Conductor - BlackPart #: OLF221818
Mfg #: 221818
Manufacturer: LAPPExtremely oil-resistant and flexible tray cable
SERIES: ÖLFLEX® TRAY II / TRAY II CY
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.587
NOMINAL OD (MM): 14.9
VOLTAGE: 600V
TRAY RATINGS: UL ITC-ER, UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC, Direct Burial (ITC)
UL STYLE / STANDARD: UL 13, UL 1063, UL 1277, UL 1690, UL 2250
-
251617IB - LAPP ÖLFLEX® AUTO-I - 16 AWG 17 Conductors - GrayPart #: OLF251617IB
Mfg #: 251617IB
Manufacturer: LAPPHeavy duty flexible tray cable with color-coded conductors for DC or AC control wiring
SERIES: ÖLFLEX® AUTO-I
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Elastomer (TPE)
NOMINAL OD (IN): 0.638
NOMINAL OD (MM): 16.1
VOLTAGE: 1000V
TRAY RATINGS: UL TC-ER
STANDARDS/APPROVALS: UL Approved, CE Approved, UL WTTC
-
602018 - LAPP ÖLFLEX® 190 Unshielded Multiconductor Cable - 20 AWG 18 Conductor - GrayPart #: OLF602018
Mfg #: 602018
Manufacturer: LAPPExtremely oil-resistant flexible power and control cable
SERIES: ÖLFLEX® 190 / 190 CY
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.487
NOMINAL OD (MM): 12.4
VOLTAGE: 600V
TRAY RATINGS: UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC
UL STYLE / STANDARD: UL 13, UL 2277
-
251819IB - LAPP ÖLFLEX® AUTO-I - 18 AWG 19 Conductors - GrayPart #: OLF251819IB
Mfg #: 251819IB
Manufacturer: LAPPHeavy duty flexible tray cable with color-coded conductors for DC or AC control wiring
SERIES: ÖLFLEX® AUTO-I
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Elastomer (TPE)
NOMINAL OD (IN): 0.583
NOMINAL OD (MM): 14.8
VOLTAGE: 1000V
TRAY RATINGS: UL TC-ER
STANDARDS/APPROVALS: UL Approved, CE Approved, UL WTTC
-
221612 - LAPP ÖLFLEX® TRAY II Unshielded Flexible Tray Cable - 16 AWG 12 Conductor - BlackPart #: OLF221612
Mfg #: 221612
Manufacturer: LAPPExtremely oil-resistant and flexible tray cable
SERIES: ÖLFLEX® TRAY II / TRAY II CY
CONDUCTOR MATERIAL: Bare copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.565
NOMINAL OD (MM): 14.4
VOLTAGE: 600V
TRAY RATINGS: UL ITC-ER, UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC, Direct Burial (ITC)
UL STYLE / STANDARD: UL 13, UL 1063, UL 1277, UL 1690, UL 2250